Frequency Range 1.5 – 30MHz, 50-54 Mhz
Line Impedance 50 ohms nominal, <1.05 V.S.W.R. insertion
Insertion Loss .05 dB or less
Line Connections SO-239 female (Type-N, and 7/16 DIN optional)
Power Ranges 1 to 3.005 watts (3 KW HF) - Limited by VSWR to the limits of the connector
VSWR Range 1.00 to 99.00
Accuracy < ±3% as measured against NIST traceable calibrated instruments
Resolution 10 Bit A/D – 4 overlapping channels of auto ranging = 12 Bit effective resolution
Peak Power Capture Time < 10 milliseconds
VSWR Alarm Relay Actuation time < 45 milliseconds
Bar Graph Response > 30Hz
VSWR Alarm Off, 1.5, 2.0, 2.5, 3.0 – relay programmable to open or close on trip
Low Power Monitor Alarm Off, 5, 50, 100, 250, 500, 1,000, 2,000 watts - NC and NO relay contacts are available
High Power Monitor Alarm Off, 175, 225, 700, 1,100, 1,600, 2,600, 3,000
Alarm Relay Contacts .5 Ampere 50 volts AC/DC
Control Manual front panel (stand alone) or via RS232 – application software
Power Required 12 - 15V DC at 600 ma
Temperature of Operation -35C to +25C
Regulatory Testing and Certification Exceeds FCC Class B (tested) and CE - both emissive and conductive (tested) as
well as EMP 4 KV and 8 KV on cables
|